Search

Cooling unit

We offer a wide range of cooling units, each adapted to the unique needs of the current installation. Together with the milk cooling tank and the control unit, the cooling unit makes up an optimized, high-quality, energy-efficient and environmentally sustainable cooling solution.

For horizontal milk cooling tanks, the cooling unit can be attached to or separated from the tank. Availability of the attached cooling unit depends on the size and cooling capacity of the cooling system as well as the type of milking system.

All our cooling units are developed and produced by us in our own factories. This ensures great quality and offers the opportunity to customize the cooling unit and cooling capacity to the requirements on each individual farm, regarding e.g. milk quantity, ambient temperature, cooling time, collection frequency, etc.

A cooling system from Wedholms means simple installation as well as cost-efficient operation, developed to minimize the environmental impact.

Read more

ATTACHED COOLING UNITS

There are many advantages with an attached cooling unit; easy transportation, quick and cheap installation and no need to fill the refrigerant on farm. With an attached cooling unit, you get a compact plug & play solution, perfectly adapted to your needs. The possibility to get an attached cooling unit on your tank depends on the number and size of the compressors and thus the cooling capacity and cooling class. For robotic milking, the cooling capacity is lower and thus attached cooling is possible even for bigger tank sizes. Please contact your local dealer or Wedholms directly to find out if an attached cooling unit is an alternative for you.

In markets with hot climate, we recommend to place the cooling unit outdoors since it might be hard to achieve sufficient ventilation of the heat produced by the cooling unit. Placement outdoors is possible with a separated cooling unit.

Advantages with the attached cooling unit;

  • Compact solution
  • Easy transportation
  • Quick and cheap installation
  • No need to fill refrigerant on farm

SEPARATED COOLING UNITS

With a separated cooling unit, you have full flexibility and it is also a space-saving solution because you can place the cooling unit outside of the milk room, either in a machine room or outside the building. Note that if there is a height difference, or the distance between the cooling unit and the milk cooling tank is more than 6-8 meters, we recommend to install a receiver and a magnetic valve to secure a problem-free performance of the cooling solution.

Here you can read more about the receiver and magnetic valve.

Separate cooling units are also available as aftermarket products and can be used for a variety of purposes. Thus, a cooling unit from Wedholms can be used for many purposes, not necessarily connected to milk production.

You can find more information and put an order for a separate cooling unit on our webshop.

Please contact your local dealer or Wedholms directly if you have any questions.

Find your local dealer .

Contact Wedholms directly.

The separated cooling unit can be placed indoors or outdoors. The standard length of the electric cables is 10 meters for horizontal tanks. In regions with hot climate, we recommend to place the cooling unit outdoors since it might be hard to achieve sufficient ventilation of the heat produced by the cooling unit.

Advantages with a separated cooling unit;

  • Space-saving
  • Flexible placement
  • Available for aftermarket

COOLING CLASS

As standard, the cooling capacity is calculated for B-class, meaning 32 degrees Celsius as ambient temperature in the milk room. However, in countries with a hot climate, an upgrade to A-class might be necessary. The cooling capacity is then calculated for an ambient temperature of 38 degrees. There is a fixed price for A-class, depending on the milk flow, and it is calculated per compressor. The adaption for A-class must be made in the factory when building the cooling unit. In hot climate, we generally recommend to put the cooling unit outside to prevent cooling problems during summer time.

Here you can read more about our cooling units.

Want to learn more or order this product?

Our sales team are ready to help you out and answer all your questions:

Click to view large image.

Product sheets and docs:
Related products:
Horizontal milk cooling tanks 1,600 to 30,000 litres »

Wedholm's horizontal milk cooling tanks combine sustainability, energy efficiency, and performance.

Vertical milk cooling tanks (Silo) 5,000 to 50,000 litres »

The demand for large-volume milk tanks is continuously increasing, which makes storage space a critical issue. Wedholms’ vertical silo tanks provide an excellent cooling solution when space is limited.

Open milk cooling tanks »

Our basic model of open milk cooling tanks with manual cleaning, DFOH (horisontal – rectangular shape), are available in several sizes and are very easy to operate.